Round aluminum magnet wire from 0.06 mm to 10.0 mm, polyester to polyimide enamel, Class 130 to 240, for transformers, motors and ballasts.
| Size range | 0.06–10.0 mm (AWG 4–32) |
|---|---|
| Conductor | Electrical-grade annealed aluminum, Al ≥ 99.5% |
| Thermal class | 130, 155, 180, 200, 220, 240 °C |
| Standards | IEC 60317, NEMA MW 1000, JIS C 3202, GB/T 6109 |
| MOQ | 500 kg per size |
| Lead time | 22–30 days |
Aluminum carries about 61% of copper's conductivity at roughly 30% of its weight, so an aluminum winding of equal resistance weighs about half as much and usually costs less. That trade is why distribution transformer, ballast and fan motor builders have moved large volumes to aluminum.
We draw electrical-grade aluminum rod, anneal it, and enamel it with the same insulation systems we use on copper: PEW, EIW, AIW, EI/AIW and PIW, in grades 1 to 3.
For equal resistance an aluminum winding weighs roughly 50% of a copper one.
Aluminum prices are lower and less volatile than copper.
Enamel systems from Class 130 up to Class 240 polyimide.
Samples available so you can qualify the wire on your own winder.
| Conductor | Electrical-grade annealed aluminum, Al ≥ 99.5% |
|---|---|
| Diameter range | 0.06–10.0 mm (AWG 4–32, SWG 6–30) |
| Resistivity at 20 °C | ≤ 0.02826 Ω·mm²/m |
| Insulation | PEW, EIW, AIW, EI/AIW, PIW |
| Thermal class | 130, 155, 180, 200, 220, 240 °C |
| Enamel build | Grade 1, Grade 2, Grade 3 |
| Standards | IEC 60317, NEMA MW 1000, JIS C 3202, GB/T 6109 |
| Certification | UL, ISO 9001, ISO 14001, RoHS, SGS |
| Packing | PT-15 to PT-270 plastic spools or plywood spools |
| MOQ | 500 kg per size |
| Lead time | 22–30 days |
Sizes and builds outside this table can be made on request. Tell us the dimension, insulation and standard and we will confirm feasibility.
| Spools | PT-15 to PT-270 plastic spools or plywood spools |
|---|---|
| Outer packing | Cartons or fumigation-free wooden pallets, moisture-proof film |
| Labels | Size, insulation, thermal class, net weight, lot number, date; OEM labels available |
| MOQ | 500 kg per size |
| Lead time | 22–30 days |
| Trade terms | FOB Shanghai, CIF, DAP; T/T or L/C at sight |
| Samples | Free sample spool with test report |
It conducts about 61% as well, so the cross-section must be about 1.6 times larger for equal resistance. In exchange the winding is lighter and usually cheaper. Where space is tight, copper still wins.
AWG 4 to AWG 32 and metric 0.06–10.0 mm. Common sizes such as 0.65 mm (about AWG 22) and 1.4 mm are produced regularly.
Use crimp connectors rated for aluminum, ultrasonic welding or TIG welding. Ordinary tin-lead soldering does not wet aluminum.