Reference

AWG to mm magnet wire size chart with resistance per metre

Bare diameter, cross-section and DC resistance for AWG 4 to AWG 46 in copper and aluminum.

AWG to mm magnet wire size chart with resistance per metre

Key takeaways

  • Every 3 AWG steps halve the cross-section area; every 6 steps halve the diameter.
  • AWG 10 is 2.588 mm, AWG 20 is 0.812 mm, AWG 30 is 0.255 mm and AWG 40 is 0.0799 mm.
  • Enameled overall diameter is larger than bare; check the grade 1, 2 or 3 build.
  • Use our wire gauge calculator for any size, including SWG and aluminum resistance.

How AWG is defined

American Wire Gauge is a logarithmic scale. The bare diameter in millimetres is d = 0.127 × 92^((36 − n) / 39), where n is the gauge number. A smaller gauge number means a thicker wire. The table below uses that formula with resistivity 0.01724 Ω·mm²/m for copper and 0.02826 Ω·mm²/m for aluminum at 20 °C.

For any size not listed, use the wire gauge calculator.

AWG to mm conversion with resistance
AWGDiameter mmDiameter inArea mm²Copper Ω/kmAluminum Ω/km
45.18940.204321.15060.821.34
54.62130.181916.77321.031.68
64.11540.162013.30181.302.12
73.66490.144310.54881.632.68
83.26360.12858.36562.063.38
92.90640.11446.63422.604.26
102.58820.10195.26123.285.37
112.30480.09074.17234.136.77
122.05250.08083.30885.218.54
131.82780.07202.62406.5710.77
141.62770.06412.08098.2813.58
151.44950.05711.650210.4517.12
161.29080.05081.308713.1721.59
171.14950.04531.037816.6127.23
181.02370.04030.823020.9534.34
190.91160.03590.652726.4143.30
200.81180.03200.517633.3154.60
210.72290.02850.410542.0068.84
220.64380.02530.325552.9686.81
230.57330.02260.258266.78109.47
240.51060.02010.204784.21138.04
250.45470.01790.1624106.18174.06
260.40490.01590.1288133.90219.48
270.36060.01420.1021168.84276.77
280.32110.01260.0810212.90348.99
290.28590.01130.0642268.47440.07
300.25460.01000.0509338.53554.92
310.22680.00890.0404426.88699.74
320.20190.00800.0320538.28882.36
330.17980.00710.0254678.761112.64
340.16010.00630.0201855.911403.01
350.14260.00560.01601079.281769.16
360.12700.00500.01271360.942230.87
370.11310.00450.01001716.122813.08
380.10070.00400.00802163.983547.23
390.08970.00350.00632728.734472.97
400.07990.00310.00503440.875640.31
410.07110.00280.00404338.867112.30
420.06330.00250.00325471.208968.45
430.05640.00220.00256899.0511309.00
440.05020.00200.00208699.5414260.39
450.04470.00180.001610969.9217982.02
460.03980.00160.001213832.8222674.91

Bare vs enameled diameter

The table gives bare conductor size. Enamel adds a few hundredths of a millimetre depending on size and build. Grade 1 is the thinnest build, grade 2 (heavy) is the most common, and grade 3 is used where extra dielectric strength is needed. When you calculate fill factor, use the maximum overall diameter from IEC 60317 or NEMA MW 1000 for the chosen grade.

AWG vs SWG

Standard Wire Gauge (SWG) is the British imperial gauge still used in the UK, India, Africa and the Middle East. The numbers do not match AWG: SWG 20 is 0.914 mm while AWG 20 is 0.812 mm. Always confirm which gauge a drawing means, or quote in millimetres.

Ordering tip

On your RFQ, state the bare diameter in mm, the insulation type, the thermal class and the build grade. "1.0 mm EIW Class 180 grade 2" is unambiguous; "AWG 18 magnet wire" is not.

Frequently asked questions

What is AWG 22 in mm?

AWG 22 is 0.644 mm bare diameter, with a cross-section of 0.326 mm².

How many mm is AWG 10?

AWG 10 is 2.588 mm bare diameter, 5.26 mm² cross-section.

Need help choosing?

Send your application and operating temperature. We will recommend the wire and quote it.